Pneumatech ADW-3200 Refrigerated Air-Gas Dryer

Return to Main Equipment Page

Back to Air Compressors & Accessories

[Click to enlarge] [Click to enlarge] [Click to enlarge] [Click to enlarge]
Pneumatech ADW-3200 Non-Cycling Refrigerated Air-Gas Dryer (Pic2)
Pneumatech ADW-3200 Non-Cycling Refrigerated Air-Gas Dryer (Pic1)
Pneumatech ADW-3200 Non-Cycling Refrigerated Air-Gas Dryer (Pic3)
Pneumatech ADW-3200 Non-Cycling Refrigerated Air-Gas Dryer (Pic4)
[Click to enlarge]
Pneumatech ADW-3200 Non-Cycling Refrigerated Air-Gas Dryer (Pic5)

Qty 1: Pneumatech Model ADW-3200 Non-Cycling Refrigerated Air/Gas Dryer, S/N P1011, Flow Capacity: 3200 SCFM, MAWP: 150 PSIG @ 500°F, MDMT: -20°F @ 150 PSIG, Outlet Dew Point: 39 °F +/- 2 °F, NEMA Class: 4, Refrigeration Compressor: 15 HP, Refrigerant: R-404a, Electrical: 460V/60Hz/3Ph., Dimensions: 113"L x 60"W x 99"H, Shipping Weight: 4,200 lbs., Year of Mfgr: 2002. Excellent Condition. Click for data sheet: ADW

HEAT EXCHANGER
The dryer has an air to refrigerant heat exchanger (evaporator) where the refrigerant is used to cool the compressed air. Heat exchanger design is a shell and tube. The heat exchanger (evaporator), separator and associated piping are modularly assembled and individually insulated.

SEPARATOR AND DRAIN
The dryer is complete with a centrifugal separator and automatic type drain valve. The centrifugal separator maximizes removal of moisture, emulsion and particle impurities. The separator uses the five principals of separation: velocity reduction, centrifugal force, impingement, directional change and agglomeration to efficiently remove water and contaminants.

REFRIGERATION COMPRESSOR
The dryer has a high efficient hermetic type compressor. The compressor is standard with internal thermal overload protection.

CONDENSER
Equipped with water-cooled refrigeration condenser, water regulating valve and strainer.

REFRIGERATION SYSTEM CONTROL
The dryer is equipped with a hot gas bypass valve to automatically adjust the refrigerant suction pressure during varying load conditions, maintain a given dew point, and help to prevent dryer freeze up. A thermal expansion valve is standard.

INSTRUMENTATION
Pneumatech's Digital Dry Guard Control (DDG) which monitors the following:
Air in temperature
Refrigerant suction temperature
Condenser water inlet temperature
Fahrenheit or Centigrade selection
Alarm indicator light
Compressor running light
Service due light
Auto drain

SML RESOURCES INTERNATIONAL
FOR INQUIRIES CONTACT
ROY LEADER